Collection of frequently used formulas for RF, Microwaves, Power, Voltage, Current and more.

FIELD STRENGTH & POWER DENSITY POWER  
dBµV/m to V/m V/m = 10 (((dBµV/m) -120) / 20) dBm to Watts W = 10 ((dBm 30)/10)
V/m to dBµV/m dBµV/m = 20 log(V/m) + 120 Watts to dBm dBm = 10log(W) + 30
dBµV/m to dBmW/m² dBmW/m² = dBµV/m 115.8 dBW to Watts W = 10 (dBW / 10)
dBmW/m² to dBµV/m dBµV/m = dBmW/m² + 115.8 Watts to dBW dBW = 10log(W)
dBµV/m to dBµA/m dBµA/m = dBµV/m 51.5 dBW to dBm dBm = dBW + 30
dBµA/m to dBµV/m dBµV/m = dBµA + 51.5 dBm to dBW dBW = dBm - 30
dBµA/m to dBpT DBpT = dBµA/m + 2    
dBpT to dBµA/m dBµA/m = dBpT 2 CURRENT  
W/m² to V/m V/m = SQRT(W/m² * 377) dBµA to µA µA = 10 (dBµA / 20)
V/m to W/m² W/m² = (V/m)² / 377 µA to dBµA dBµA = 20 log(µA)
µT to A/m A/m = µT / 1.25 dBA to A A = 10 (dBA / 20)
A/m to µT µT = 1.25 * A/m A to dBA dBA = 20log(A)
    dBA to dBµA dBµA = dBA + 120
LOOP ANTENNAS dBµA to dBA dBA = dBµA -120
Correction Factors dBµA/m = dBµV + AF    
E-field (take care about E-field suppression!) dBµV/m = dBµA/m + 51.5 VOLTAGE  
  dBµV to Volts V = 10 ((dBµV 120) / 20)
    Volts to dBµV dBµV = 20 log(V) + 120
FREQUENCY / BANDS WAVELENGTH dBV to Volts V = 10 (dBV / 20)
3Hz - 30Hz (ELF) 100000km - 10000km Volts to dBV dBV = 20log(V)
30Hz - 300Hz (SLF) 10000km - 1000km dBV to dBµV dBµV = dBV +120
300Hz - 3kHz (ULF) 1000km - 100km dBµV to dBV dBV = dBµV - 120
3kHz - 30kHz (VLF) 100km - 10km    
30kHz - 300kHz (LF) 10km - 1km UNIT CONVERSIONS  
300kHz - 3MHz (MF) 1km - 100m dBm to dBµV dBµV = dBm + 107(50Ω)
3MHz - 30MHz (HF) 100m - 10m dBµV to dBm dBm = dBµV 107(50Ω)
30MHz - 300MHZ (VHF) 10m - 1m dBm to dBµA dBµA = dBm + 73(50Ω)
300MHz - 3GHz (UHF) 1m - 10cm dBµA to dBm dBm = dBµA 73(50Ω)
3GHz - 30GHz (SHF) 10cm - 1cm dBµA to dBµV dBµV = dBµA + 34(50Ω)
30GHz - 300GHz (EHF) 1cm - 1mm dBµV to dBµA dBµA = dBµV 34(50Ω)
 
 